FOREX Press I. J. of Electrical & Electronics Research
Support Open Access

Research Article |

Performance Evaluation of Fuzzy One Cycle Control Based Custom Power Device for Harmonic Mitigation

Author(s): Vasupalli Manoj1, Dr. Prabodh Khampariya2 and Dr. Ramana Pilla3

Publisher : FOREX Publication

Published : 30 September 2022

e-ISSN : 2347-470X

Page(s) : 765-771




Vasupalli Manoj*, Research Scholar, Department of Electrical Engineering, Sri Satya Sai University of Technology & Medical Sciences, Bhopal, India; Email: manojv287@gmail.com

Dr. Prabodh Khampariya, Professor, Department of EEE, Sri Satya Sai University of Technology & Medical Sciences, Bhopal, India

Dr. Ramana Pilla*, Professor, Department of EEE, GMR Institute of Technology, Rajam, India; Email: ramana.pilla@gmrit.edu.in

    [1] A. Alduraibi, J. Yaghoobi, D. Solatialkaran, and F. Zare, “A Modular Power Converter with Active Front-End System to Mitigate Harmonics in Distribution Networks,” IEEE J. Emerg. Sel. Top. Power Electron., vol. 9, no. 2, pp. 1725–1735, Apr. 2021, doi: 10.1109/JESTPE.2020.2993786.[Cross Ref]
    [2] R. Pandurangan, P. Kaliannan, and P. Shanmugam, “Effects of Current Distortion on DC Link Inductor and Capacitor Lifetime in Variable Frequency Drive Connected to Grid with Active Harmonic Filter,” IEEE Trans. Ind. Appl., vol. 57, no. 1, pp. 492–505, Jan. 2021, doi: 10.1109/TIA.2020.3028555.[Cross Ref]
    [3] L. F. J. Meloni, F. L. Tofoli, A. J. J. Rezek, and E. R. Ribeiro, “Modeling and Experimental Validation of a Single-Phase Series Active Power Filter for Harmonic Volt age Reduction,” IEEE Access, vol. 7, pp. 151971–151984, 2019, doi: 10.1109/ACCESS.2019.2947917.[Cross Ref]
    [4] A. Bendicks, T. Dörlemann, S. Frei, N. Hees, and M. Wiegand, “Active EMI Reduction of Stationary Clocked Systems by Adapted Harmonics Cancellation,” IEEE Trans. Electromagn. Compat., vol. 61, no. 4, pp. 998–1006, Aug. 2019, doi: 10.1109/TEMC.2018.2854965.[Cross Ref]
    [5] M. Wang, X. Wang, J. Qiao, and L. Wang, “Improved Current Decoupling Method for Robustness Improvement of LCL-type STATCOM Based on Active Disturbance Rejection Control,” IEEE Access, vol. 7, pp. 121781–121792, 2019, doi: 10.1109/ACCESS.2019.2931747.[Cross Ref]
    [6] L. Wang, X. Han, C. Ren, Y. Yang, and P. Wang, “A Modified One-Cycle-Control-Based Active Power Filter for Harmonic Compensation,” IEEE Trans. Ind. Electron., vol. 65, no. 1, pp. 738–748, Jan. 2018, doi: 10.1109/TIE.2017.2682021.[Cross Ref]
    [7] K. H. Tan, F. J. Lin, and J. H. Chen, “DC-Link voltage regulation using RPFNN-AMF for Three-Phase active power filter,” IEEE Access, vol. 6, pp. 37454–37463, Jun. 2018, doi: 10.1109/ACCESS.2018.2851250.[Cross Ref]
    [8] J. Morales, L. G. De Vicuna, R. Guzman, M. Castilla, and J. Miret, “Modeling and Sliding Mode Control for Three-Phase Active Power Filters Using the Vector Operation Technique,” IEEE Trans. Ind. Electron., vol. 65, no. 9, pp. 6828–6838, Sep. 2018, doi: 10.1109/TIE.2018.2795528.[Cross Ref]
    [9] S. Kumar and B. Singh, “A Multipurpose PV System Integrated to a Three-Phase Distribution System Using an LWDF-Based Approach,” IEEE Trans. Power Electron., vol. 33, no. 1, pp. 739–748, Jan. 2018, doi: 10.1109/TPEL.2017.2665526.[Cross Ref]
    [10] N. Malla, U. Tamrakar, D. Shrestha, Z. Ni, and R. Tonkoski, “Online learning control for harmonics reduction based on current controlled voltage source power inverters,” IEEE/CAA J. Autom. Sin., vol. 4, no. 3, pp. 447–457, Jul. 2017, doi: 10.1109/JAS.2017.7510541.[Cross Ref]
    [11] J. Fang, X. Li, X. Yang, and Y. Tang, “An Integrated Trap-LCL Filter with Reduced Current Harmonics for Grid-Connected Converters under Weak Grid Conditions,” IEEE Trans. Power Electron., vol. 32, no. 11, pp. 8446–8457, Nov. 2017, doi: 10.1109/TPEL.2017.2651152.[Cross Ref]
    [12] C. S. Lam, L. Wang, S. I. Ho, and M. C. Wong, “Adaptive Thyristor-Controlled LC-Hybrid Active Power Filter for Reactive Power and Current Harmonics Compensation with Switching Loss Reduction,” IEEE Trans. Power Electron., vol. 32, no. 10, pp. 7577–7590, Oct. 2017, doi: 10.1109/TPEL.2016.2640304.[Cross Ref]
    [13] R. Guzman, L. G. De Vicuna, J. Morales, M. Castilla, and J. Miret, “Model-Based Control for a Three-Phase Shunt Active Power Filter,” IEEE Trans. Ind. Electron., vol. 63, no. 7, pp. 3998–4007, Jul. 2016, doi: 10.1109/TIE.2016.2540580.[Cross Ref]
    [14] G. A. De Almeida Carlos, C. B. Jacobina, E. C. Dos Santos, E. L. L. Fabrício, and N. Rocha, “Shunt Active Power Filter With Open-End Winding Transformer and Series-Connected Converters,” IEEE Trans. Ind. Appl., vol. 51, no. 4, pp. 3273–3283, Jul. 2015, doi: 10.1109/TIA.2015.2394318.[Cross Ref]
    [15] T. L. Lee, Y. C. Wang, J. C. Li, and J. M. Guerrero, “Hybrid active filter with variable conductance for harmonic resonance suppression in industrial power systems,” IEEE Trans. Ind. Electron., vol. 62, no. 2, pp. 746–756, Feb. 2015, doi: 10.1109/TIE.2014.2347008.[Cross Ref]
    [16] S. Bai and S. M. Lukic, “Unified active filter and energy storage system for an MW electric vehicle charging station,” IEEE Trans. Power Electron., vol. 28, no. 12, pp. 5793–5803, 2013, doi: 10.1109/TPEL.2013.2245146.[Cross Ref]
    [17] J. Dannehl, M. Liserre, and F. W. Fuchs, “Filter-based active damping of voltage source converters with LCL filter,” IEEE Trans. Ind. Electron., vol. 58, no. 8, pp. 3623–3633, Aug. 2011, doi: 10.1109/TIE.2010.2081952.[Cross Ref]
    [18] A. Hamadi, S. Rahmani, and K. Al-Haddad, “A hybrid passive filter configuration for VAR control and harmonic compensation,” IEEE Trans. Ind. Electron., vol. 57, no. 7, pp. 2419–2434, Jul. 2010, doi: 10.1109/TIE.2009.2035460.[Cross Ref]
    [19] M. A. M. Radzi and N. A. Rahim, “Neural network and bandless hysteresis approach to control switched capacitor active power filter for reduction of harmonics,” IEEE Trans. Ind. Electron., vol. 56, no. 5, pp. 1477–1484, 2009, doi: 10.1109/TIE.2009.2013750.[Cross Ref]
    [20] C. Qiao, T. Jin, and K. M. Smedley, “One-cycle control of three-phase active power filter with vector operation,” IEEE Trans. Ind. Electron., vol. 51, no. 2, pp. 455–463, Apr. 2004, doi: 10.1109/TIE.2004.825223.[Cross Ref]
    [21] H.-H. Kuo, S.-N. Yeh, and J.-C. Hwang, “Novel analytical model for design and implementation of three-phase active power filter controller”, doi: 10.1049/ipepa:20010433.[Cross Ref]
    [22] Sandhya Kulkarni and Archana Thosar (2022), Performance Analysis of Fault Tolerant Operation of PMSM using Direct Torque Control and Fuzzy Logic Control. IJEER 10(2), 297-307. DOI: 10.37391/IJEER.100240.[Cross Ref]
    [23] M Rupesh, Dr. T S Vishwanath (2021), Fuzzy and ANFIS Controllers to Improve the Power Quality of Grid Connected PV System with Cascaded Multilevel Inverter. IJEER 9(4), 89-96. DOI: 10.37391/IJEER.090401.[Cross Ref]
    [24] Ganiyu Adedayo Ajenikoko, Ridwan Abiola Oladepo (2018), Impact of System Average Interruption Duration Index Threshold on the Reliability Assessment of Electrical Power Distribution Systems. IJEER 6(2), 17-31. DOI: 10.37391/IJEER.060203. http://ijeer.forexjournal.co.in/papers-pdf/ijeer-060203.pdf[Cross Ref]
    [25] Prof. Kalyani Kurundkar and Dr. G. A. Vaidya (2021), Application of HFPSO-TOPSIS approach for optimally locating and sizing of reactive power compensating devices for voltage control ancillary service. IJEER 9(3), 16-26. DOI: 10.37391/IJEER.090301. https://ijeer.forexjournal.co.in/archive/volume-9/ijeer-090301.html[Cross Ref]

Vasupalli Manoj, Dr. Prabodh Khampariya and Dr. Ramana Pilla (2022), Performance Evaluation of Fuzzy One Cycle Control Based Custom Power Device for Harmonic Mitigation. IJEER 10(3), 765-771. DOI: 10.37391/IJEER.100358.