Abstract
Cascaded H-bridge multilevel inverters are becoming increasingly used in applications such as distribution systems, electrical traction systems, high voltage direct conversion systems, and many others. Despite the fact that multilevel inverters contain a large number of control switches, detecting a malfunction takes a significant amount of time. In the fault switch configurations diode included for freewheeling operation during open-fault condition. During short circuit fault conditions are carried out by the fuse, which can reveal the freewheeling current direction. The fault category can be identified independently and also failure of power switches harmed by the functioning and reliability of cascaded H-bridge multilevel inverters. This paper investigates the effects and performance of open and short switching faults of multilevel inverters. Output voltage characteristics of five level MLI are frequently determined from distinctive switch faults with modulation index value of 0.85 is used during simulation analysis. In the simulation study, with the modulation index value of 0.85, one second open and short circuit faults are generated for the location of the defective switch. Fault is identified automatically by means of artificial neural network technique using sinusoidal pulse width modulation based on distorted total harmonic distortion and managed by its own. The proposed topology is to be design and evaluate using MATLAB/Simulink platform
Keywords: Artificial Neural Network
, Fast Fourier Transform
, Multilevel inverter
, Sinusoidal Pulse Width Modulation
, Total Harmonic Distortion
Parimalasundar E, Associate Professor, Department of EEE, Sree Vidyanikethan Engineering College, Tirupati, India; Email: parimalasundar.e@vidyanikethan.edu
Jayakumar S, Assistant Professor, Department of EEE, KCG College of Technology, Chennai, India
Ravikumar R, Professor, Department of EEE, Joginpally B. R. Engineering College, Hyderabad, India
Suresh K, Associate Professor, Department of EEE, Sree Vidyanikethan Engineering College, Tirupati, India
[1] H.K. Jahan, F. Panahandeh, M. Abapour and S. Tohidi, “Reconfigurable Multilevel Inverter with Fault-Tolerant Ability”, IEEE Transactions on Power Electronics, vol. 33, no. 9, pp. 7880-7893, 2018. doi: https:// doi: 10.1109/TPEL.2017.2773611.[Cross Ref]
[2] M.M Haji-Esmaeili, M. Naseri, H. Khoun-Jahan and M. Abapour, “Fault-Tolerant and Reliable Structure for a Cascaded Quasi-Z-Source DC–DC Converter”, IEEE Transactions on Power Electronics, vol. 32, no. 8, pp. 6455-6467, 2017. doi: https:// doi: 10.1109/TPEL.2016.2621411.[Cross Ref]
[3] M. Jalhotra, S.P. Gautam, L. Kumar, S. Gupta and A.H. Chander, “Fault Tolerance and Energy Sharing Analysis of a Single-Phase Multilevel Inverter Topology”, Proceedings - IECON 2018, 44th Annual Conference of the IEEE Industrial Electronics Society, pp. 1209-1213, 2018. doi: https:// doi: 10.1109/IECON.2018.8591853.[Cross Ref]
[4] J. Amini and M. Moallem, “A Fault-Diagnosis and Fault-Tolerant Control Scheme for Flying Capacitor Multilevel Inverters”, IEEE Transactions on Industrial Electronics, vol. 64, no. 3, pp. 1818-1826, 2017. doi: https://doi: 10.1109/TIE.2016.2624722.[Cross Ref]
[5] E. Babaei, S. Laali and Z. Bayat, “A Single-Phase Cascaded Multilevel Inverter Based on a New Basic Unit with Reduced Number of Power Switches”, IEEE Transactions on Industrial Electronics, vol. 62, no. 2, pp. 922-929, 2015. doi: https:// doi: 10.1109/TIE.2014.2336601.[Cross Ref]
[6] P. Ezhilvannan and S. Krishnan, “An efficient asymmetric direct current (DC) source configured switched capacitor multi-level inverter”, Journal Européen des Systèmes Automatisés, vol. 53, no. 6, pp. 853-859, 2020. doi: https://doi.org/10.18280/jesa.530611.[Cross Ref]
[7] K. Suresh and E. Parimalasundar, “A Modified Multi Level Inverter with Inverted SPWM Control”, IEEE Canadian Journal of Electrical and Computer Engineering, vol. 45, no. 2, pp.99-104, 2022. doi: https:// 10.1109/ICJECE.2022.3150367.[Cross Ref]
[8] G. Kiran Kumar, E. Parimalasundar, D. Elangovan, P. Sanjeevikumar, and F. Lannuzzo. “Fault Investigation in Cascaded H-Bridge Multilevel Inverter through Fast Fourier Transform and Artificial Neural Network Approach”, Energies, vol. 13, pp. 01-19, 2020. doi: https:// doi.org/10.3390/en13061299.[Cross Ref]
[9] K. Suresh and E. Parimalasundar, “A novel dual-leg DC-DC converter for wide range DC-AC conversion”, Automatika, vol. 63, no. 3, pp. 572-579, 2022. doi: https:// doi.org/10.1080/00051144.2022.2056809.[Cross Ref]
[10] Z. Huang, Z. Wang and H. Zhang, “Multiple Open-Circuit Fault Diagnosis Based on Multistate Data Processing and Subsection Fluctuation Analysis for Photovoltaic Inverter”, IEEE Transactions on Instrumentation and Measurement, vol. 67, no. 3, pp. 516-526, 2018. doi: https:// doi: 10.1109/TIM.2017.2785078.[Cross Ref]
[11] S. Khomfoi and L. M. Tolbert, "Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques," in IEEE Transactions on Industrial Electronics, vol. 54, no. 6, pp. 2954-2968, Dec. 2007, doi: 10.1109/TIE.2007.906994.[Cross Ref]
[12] Chitra S, Jayakumar J, Venkateshkumar P, Shanty Chacko, Sivabalan (2022), Identification of Power Leakage and Protection of Over Voltage in Residential Buildings. IJEER 10(1), 51-56. DOI: 10.37391/IJEER.100107.[Cross Ref]
[13] Prof. Kalyani Kurundkar and Dr. G. A. Vaidya (2021), Application of HFPSO-TOPSIS approach for optimally locating and sizing of reactive power compensating devices for voltage control ancillary service. IJEER 9(3), 16-26. DOI: 10.37391/IJEER.090301.https://ijeer.forexjournal.co.in/archive/volume-9/ijeer-090301.html[Cross Ref]
[14] Vugar Abdullayev, Ranjeet Pratap Singh Bhadouria (2020), Overview of the Conversion of Traditional Power Grid to Internet Energy. IJEER 8(4), 37-40. DOI: 10.37391/IJEER.080401. http://ijeer.forexjournal.co.in/archive/volume-8/ijeer-080401.html[Cross Ref]
Parimalasundar E, Jayakumar S, Ravikumar R, Suresh K (2022), Investigation analysis of open circuit and short circuit fault on cascaded H-bridged multilevel inverter using artificial neural network approach. IJEER 10(2), 320-326. DOI: 10.37391/IJEER.100243.